Table Top Steam Autoclaves/Sterilizers
Vertical Autoclaves / Sterilizers
Large Pulsant Vacuum Autoclaves /Sterilizers
Hot Air Autoclaves / Sterilizers
 
GMQ.C Series Fully Automatic Hot Air Autoclaves/Sterilizers
DHG Series Heating and Drying Oven
GRX Series Hot Air Sterilizer
GZX Series Hot Air Sterilizer
Washer Disinfectors
Table Top Ultrasonic Cleaners
Industrial Ultrasonic Cleaners
Accessories
New Products


Products>>Vertical Autoclaves/Sterilizers

   
CLASS B-TMQ.CV 5070P 135L

TMQ.CV Series Table Top Pulsation Steam Vacuum Sterilizer 
Application:
With pressure steam as medium, it is used in sterilizing medical dressing, utensils, class A, Class B hollow lumen instruments, catheters, and waste in the operating room, clinic department, CSSD, biological laboratories and other healthcare sectors.

Main Features:
●PLC control technology, colored touch screen;
●Affusion, pulse vacuum, heating, sterilizing, exhaust, vacuum drying whole process are automatically controlled by program;
●Dynamic pulsant vacuum exhaust air: Vacuum up to-0.08MPa, can exhaust steam in medical dressings, Class A hollow lumen instruments;
●Pulsation behind vacuum drying system to ensure parcels dry .
●High-performance built-in steam generator and steam-water separator devices, ensure quality steam, without external steam source;
●With instruments, dressing, rubber and customized procedures for user's optional;
●With manually Bowie & Dick leaking and vacuum testing procedures;
●0.22μm HEPA filter can ensure the vacuum steam is amicrobic, to avoid further contamination;
●Dynamically LCD display temperature, pressure, time, sterilizing status, malfunction alarm;
●Equipped with maintenance reminding function. User-friendly maintenance equipment and replacement of wearing parts;
●Beep reminding when finishing;
●Mini printer is optional to real-time record the whole sterilizing process and malfunction informations.

Safety Protection:
●Over-temperature protection: Over the setting temperature, system automatically cut off power and display alarm;
●Door safety interlock devices: Only the doors closed in place, sterilizers to start working procedures. If there is dangerous pressure in the chamber, the door can not be opened;
●Dual overpressure protection: Automatic releasing safety valve: If pressure is over design , safety valve will open to release; Overpressure automatic protection control: If pressure is over setting, safety valve will automatic release and display alarm;
●Anti-dry alarm: below the water level, automatically cut off the heating power, and display alarm information;
● Electronic circuit safety devices: AC main circuit with a short-circuit protection, over-voltage DC control circuits with overload protection.

Main Technical Parameters:
Designed Pressure: -0.1/0.28MPa Max. Working Pressure: 0.23MPa
Pressure Display Precision: ± 0.1KPa
Sterilization Temperature Range: 105℃~136℃
Temperature Display Precision: ±0.1℃
Temperature uniformity: ≦±0.5℃
Chamber Material: SUS304 stainless steel

   



Contact Information
Yongfeng Enterprise Co., Ltd.
Add: No.1, Lane 110, Shengfeng Road, Ningbo, 315010, China
Tel:  86-574-87255354
Fax: 86-574-87125894
Web Site: http://www.china-sterilizers.com, http://autoclave.chinese-suppliers.com
E-mail: info@china-sterilizers.com